My guess is that directory is an empty string for some reason. Mixone I think this is because the code is not minimal. Also the stack trace is not full.
Show 5 more comments. Active Oldest Votes. This happens if you are trying to open a file, but your path is a folder. This can happen easily by mistake. Improve this answer. Gulzar Gulzar I wish the original asker would accept this as the answer. There are many, many questions about this error, and this is the only answer that really seems to be right. Often this error occurs despite the file having correct permissions set, and so the answer has to be something else.
This is it. Add a comment. EDIT There are basically three main methods of achieving administrator execution privileges on Windows.
Running as admin from cmd. You can do this two ways: Manually Find cmd. A small pop-up list containing various administrator tasks will appear. Select Command Prompt Admin Travel to your project directory Run your program By doing that you are running as Admin so this problem should not persist B Creating shortcut with elevated privileges Create a shortcut for python. Mixone Mixone 1, 1 1 gold badge 13 13 silver badges 22 22 bronze badges. What if this hapens from PyCharm?
I am unable to give admin privilages to python. In that case you probably need to contact your IT support team. Also try running PyCharm as an Admin, if you can, not the python. Mixone Why does the OP need admin privileges? If he owns the destination folder, and owns the program, then surely the levels match? How does one debug what level you're running at, and what level you need for any specific destination? Make sure the file you are trying to write is closed first.
Posted Apr pm Gus'O. Hi, what i did to solve my problem giving the same message was to go to IIS and check if it is configured as an Application or simply as a virtual directory. The App icon was just a folder icon. Of course the app was targeting framework 4. This solved the issue for me. But some things i did not say, 1.
I am running it locally on IIS 6. I am accessing with domain credential and not with 'pass through' authentication. Hope this helps. Krunal Rohit 2-Dec am. Well, issue was solved ages ago. RagsLuvsToCod 2-Dec am.
Add your solution here. OK Paste as. Treat my content as plain text, not as HTML. Existing Members Sign in to your account. This email is in use. Do you need your password? Submit your solution! When answering a question please: Read the question carefully. Important Follow the steps in this section carefully. Serious problems might occur if you modify the registry incorrectly. Before you modify it, back up the registry for restoration in case problems occur.
Office Office Exchange Server. Not an IT pro? Sign in. United States English. Ask a question. Quick access. Search related threads. The data will be exported only from the company that is currently open. On the logo line, you can browse to where you have a copy of your logo saved. The logo must be in the format of. The remaining line items can be used for your company information or any message you want to display on each report.
The first line is a little larger and bolder than the two lines following. An operator can be added under the Admin section. In the bottom section, there is a button for User Management. You can add new operators either as an admin or operator. When security is turned on, only an Admin can get into the Admin section.
A company exists so that the data can be separated into separate groups. While employees can be moved to another company, all imports and reports will be for the open company. To create a new company, go to the Company section, and click on Add. The only field required is the name. The rest of the top portion is for record keeping only if necessary.
The fields at the bottom determine which fields show up when a person is being added into the database. The synchronization feature in the Tools section will allow for users to do a two-way synchronization between two databases. In order to do a synchronization, these requirements must be met:. OHD recommends that FitTrack data is backed up at least once a week.
Preferably, the database will be backed up after every testing period. Data loss can occur through hard drive failure, or data corruption. The most probably cause for data corruption is loss of power to a computer. This may happen through battery failure, removal of power cord, or loss of power in a building. Keeping your data safe should be a priority for any user. Backing up the data to the same computer being used for testing is only the first step in securing data.
Backups on the same computer, called Local Backups, are helpful if any data corruption should occur. However, these would not be very useful if a hard drive crash is experienced. Click Here for tech document. Unfortunately, in mid , Windows finally outgrew FitTrack software.
Even the earliest versions of Windows still in use received security updates that prohibited Windows from connecting to a computer. This was one of the main reasons we upgraded from the FitTester to the Quantifit.
The FitTester uses a serial interface rather than a USB, and this is what finally limited the communication. It is recommended that the operator keep a spare part, and replace them at minimum once each year. Please follow these instructions when fit testing with this Scott Connector with our Kit 1 part number To prep the Rap Adapter, you must remove the spokewheel 1 on the threaded side, remove and discard the flat diaphragm 2 and then reinsert the spoke wheel gasket 3.
The Kit 1 adapter will screw into the threaded side of the Mini Rap adapter, and opposite end of the Rap with the O-ring can be inserted into the front of the respirator until it clicks into place. The only maintenance required on this Rap adapter is to be sure the rubber gasket remains clean. This part will last for many years with normal use.
The Inhalation valve must be removed from the ISI part Image shows part without diaphragm. The must be attached to the front of the respirator. First you will remove the front portion of the respirator by unscrewing the 4 screws.
The will replace the front portion of the respirator. After the part has been attached to the respirator, prop or remove the inhalation valve, then attach Kit 1 into the female threading. Since this ISI piece is not easily moved to another respirator, ideally you will want to have surrogate masks in each size of the respirator. The OSHA fit test requirement is that you must have one of each size for the test subject to try. There are two things to look for if you are having trouble getting people to pass with this respirator.
Knowledge Base Home Knowledge Base. Machine Fault: You must do the daily calibration at the beginning of each day. If the Quantifit successfully completes the dual tube calibration without an error message, this assures that the machine is operating properly and within tolerance. If the Quantifit does not complete the dual tube calibration, service might be needed. Please contact OHD customer service. Any facial hair, hair getting anywhere under the mask seal, temple hair too far forward, sunken temples or facial scarring, protrusions or blemishes, having the mask too loose or too tight, can all be reason enough to keep the Quantifit from pulling a negative pressure within the mask.
There are other obstacles that can come into play which are too numerous to list. To further check on the mask fit, do a user seal check for 10 seconds. Press the Seal Check button and take in a breath allowing for plenty of suction on the mask. If there is no felt movement when the Seal Check button is released, then the air has leaked out in those 10 seconds.
Exhalation valves may be dirty or creased allowing air to be pulled into the mask. While the inhalation valves must be removed or propped open, the exhalation valve must remain in place and maintain a good seal. On the mask, the apex of the head straps should sit on the crown of the head and not off to one side or the other.
Adapter Fault: The adapters must be kept clean and in good shape. These screws are glued into place, but can become loose over time. If the adapter had been dropped or crushed, a hairline crack might cause leakage.
The most obvious error that could take place is when the subject does not remain completely still. He or she must be instructed to hold breath, keep lips and teeth together, no swallowing, etc. Tell the subject to hold a comfortable breath. When holding a deep breath, there is more air fighting to get out of the lungs, and this could cause movement or actually be more of a challenge for the subject to hold. The Quantifit is very sensitive and will even register slight head movement.
If the Trigger button is pressed while the test subject is still breathing or inhaling, the Quantifit will display a message stating that the breath must be held before the measurement can begin. Hair, not clean-shaven, scar, or some other impediment may be breaking the surface of the mask. Test subject not holding breath properly. In rare cases, the test subject might have a hole or defect in his or her eardrum.